EXD Series Explosion Proof Transmitter

0-5 inwc through 0-5K psid

Certified for Hazardous Locations

EX approved for hazardous locations

Dylix’s EXD Series Differential Pressure Transmitter is designed and approved for use in hazardous locations. The EXD’s entirely welded 316L SST construction is hermetically sealed, making it ideal for the worst of pressure applications. CSA/CUS Explosion Proof certified for Class I Div 1 and Class I Div 2 Groups A, B, C, D.

Manufactured for extended life cycles

The EXD is built using advanced manufacturing techniques to ensure symmetry between the Hi and Lo ports. Symmetry, along with automated welding procedures and extreme environmental burn-in, give Dylix’s differential pressure products excellent performance and reliability over time and at high elevated line pressure.

Entirely welded 316L SST pressure cavities

The EXD’s pressure ports all welded 316L SST ‘O’-Ring free design makes it ideal for high cyclical applications, capillary filled systems, or applications where a guaranteed leak free system is needed.

Dylix’s Customer Service

Each transducer is delivered with a NIST traceable calibration certificate.

Standard Features:

  • Hermetically Sealed Package
  • ± 0.25% FSO Static Accuracy
  • 0-5” H2O through 0-5,000 psi

Available Options:

  • ± 0.1% FSO Static Accuracy
  • ± 0.5% FSO Thermal Error Band
  • Low Power

Product Specifications

Electrical

Excitation
EXD1 2-15 Vdc
EXD2 & EXD3 10-38 Vdc*
Output
EXD1 1-2 mV/V*
EXD2 0-5 Vdc*
EXD3 4-20 mAdc
Zero Balance ≤ 1% FSO
FSO Setting ≤ 1% FSO
Resolution Infinite (0.001% FSO usable)
Response Time
EXD1 < 50 mS
EXD2 & EXD3 < 100 mS
Insulation Resistance 1,000 M Ω @ 50 Vdc
Reverse Polarity Protected
Warm-up < 100 mS
Power Supply Effect ≤± .002% per V input
EMI/RFI Internal Filtering (EXD2, EXD3)
Short Circuit Protected Up to 40 Vdc

Environmental

Compensated Temp Range 0 to 170º F
Operating Temp Range -20 to 200º F
Storage Temp Range -40 to 250º F

Certifications

CSA/CUS Explosion Proof Class I Div 1 Groups A, B, C, D
CSA/CUS Explosion Proof Class I Div 2 Groups A, B, C, D
Master Contract Number: 229278
Certificate Number: 1658325

* Options Available

Mechanical

Pressure Ranges
Range A: 0-5” inwc through 0-30 psi
Range B: 0-30 through 0-200 psid
Range C: 0-300 through 0-1K psid
Range D: 0-2K through 0-5K psid
(Customer may specify any range/eng. unit)
Line Pressure
Range A: 1,000 psi
Range B: 1,000 psi
Range C: 3,000 psi
Range D: 2,000 psi
Proof Pressure
Range A: 1,000 psi
All others: 3X Full Scale either side
(7K psi max)*
Burst Pressure
Range A: Minimum 3K psi
Range B: Minimum 5K psi
Range C: Minimum 10K psi
Range D: Minimum 12K psi
Material
Wetted Parts 316L SST
Non-wetted Parts 316L SST plus electrical connector
Pressure Port* 1/4" NPT (Female)*
Electrical Connector 1/2" NPT (Male) conduit cable exit with 24” cable*
Dimensions Per outline O-EXD-001
Weight 18 oz. Nominal

Performance

Static Accuracy ± 0.25% FSO* (BFSL, RSS)
(Combined effects of non-linearity, hysteresis & repeatability)
Static Pressure Effect
On Zero ± 1% FSO per 1,000 psi
On Span ± 1% of reading per 1,000 psi
Repeatability ± 0.1% FSO
Temperature Effects ± 1.5% FSO over comp range
(Combined effects of Zero & FSO with reference at 70º F)
Mounting Effects Zero shifts up to 1” H2O depending on orientation
Long Term Stability ± 0.25% FSO per year

Standard Wiring

Model Output + Power - Power + Signal - Signal Case Ground
EXD1 mV/V dc 4 wire Red Black Green White Tinned Wire
EXD2 0-5 (10) Vdc 3 wire Red Black Green Tinned Wire
EXD3 4-20 mAdc 2 wire Red Black Green

**Dylix Corporation reserves the right to change specifications without prior notification. Please contact the factory for the latest revision.